Products

Ion vsvt

Single or Two-Stage Compact Vertical Packaged Unit | VS/VT

TETCO VS/VT compact vertical models provide forced-air heating and cooling with outstanding performance, whisper-quiet operation and a small footprint. They're available in single and two-stage configuration, in a variety of tonnages to fit any installation.

  • Capacity: 3/4 to 6 tons
  • Efficiency: Up to 28.3 EER / 5.6 COP
  • Full selection of commercial voltages
  • Single or two-stage compressor
  • PSC or ECM blower motor
  • Factory installed desuperheater option

Es5 yt

Two-Stage Multi-Position Vertical Packaged Unit | YT

The TETCO Commercial Series YT geothermal system delivers ducted, forced-air heating and cooling. YT models are among the most efficient models and feature whisper-quiet operation. An innovative multi-positional cabinet is field convertible to right or left return with top or side discharge.

  • Capacity: 2 to 6 tons
  • Efficiency: Up to 31.3 EER / 5.1 COP
  • Full selection of commercial voltages
  • Copeland UltraTech two-stage compressor
  • ECM blower motor
  • Factory installed desuperheater option

Es4 xt

Two-Stage Multi-Position Vertical Packaged Unit | XT

The TETCO Commercial Series XT geothermal system is a forced-air heating and cooling system that has high performance and built-in versatility. The innovative multi-positional cabinet is field convertible to upflow/downflow with right or left return and makes the XT easy to install and stock.

  • Capacity: 2 to 6 tons
  • Efficiency: Up to 35 EER / 5.4 COP
  • Voltages: 208/230V, 60Hz, 1Ph/3Ph; 460V, 60Hz, 3Ph
  • Copeland UltraTech two-stage compressor
  • ECM blower motor
  • Factory installed desuperheater

Ion zt

Two-Stage Compact Horizontal Packaged Unit | ZT

The all-new Commercial Series Compact Horizontal Packaged water source heat pump features a smaller footprint to fit between 24" O.C. trussing. The unit is field convertible for side or end discharge. It's designed for enhanced serviceability, superior efficiency, and quiet operation.

  • Capacity: 2 to 6 tons
  • Efficiency: Up to 29.8 EER / 4.4 COP
  • Voltages: 208/230V, 60Hz, 1Ph/3Ph; 265V, 60Hz, 1Ph; 460V, 60Hz, 3Ph
  • All-aluminum microchannel air coil
  • Foam enclosed braze plate heat exchanger
  • Freeze protected flow switch and sensor

Es4 ct

Two-Stage Multi-Position Hydronic Vertical Combination Unit | CT

A TETCO Commercial Series CT combination geothermal unit has the flexibility to provide forced air heating, forced air cooling, and hot water for radiant floor heating.

  • Capacity: 2 to 6 tons
  • Efficiency: Up to 32.7 EER / 5.2 COP
  • Voltages: 208/230V, 60Hz, 1Ph/3Ph; 460V, 60Hz, 3Ph
  • Copeland UltraTech 2-stage compressor
  • ECM blower motor
  • Factory installed desuperheater

Es4 ws

Single-Stage Water-to-Water Unit | WS

TETCO single-stage water-to-water models are designed to supply heated or chilled water for use in a wide range of heating and cooling applications, including radiant floor heating. These systems utilize brazed-plate heat exchangers for superior efficiency.

  • Capacity: 3 to 7 tons
  • Efficiency: Up to 24.0 EER / 4.1 COP
  • Voltages: 208/230V, 60Hz, 1Ph/3Ph; 460V, 60Hz, 3Ph
  • Copeland single stage scroll compressor
  • Thermostatic expansion valve
  • Factory installed desuperheater

Es4 wd

Two-Stage Water-to-Water Unit | WD

Commerical Series WD water-to-water models feature dual compressors to provide two-stage heating and cooling. TETCO large hydronic models supply heated or chilled water for various applications, including radiant floor heating. These systems utilize brazed-plate heat exchangers for superior efficiency.

  • Capacity: 10, 20 and 30 tons
  • Efficiency: Up to 21.8 EER / 4.3 COP
  • Voltages: 208/230V, 60Hz, 1Ph; 208/230V, 460V, 575V, 60Hz, 3Ph
  • Dual Copeland single stage scroll compressors
  • Thermostatic expansion valve
  • Factory installed desuperheater

Es4 wt

Two-Stage Water-to-Water Unit | WT

TETCO two-stage water-to-water models are designed to supply heated or chilled water for use in a wide range of heating and cooling applications, including radiant floor heating. These hydronic systems allow for constant and uniform heat distribution that eliminates hot and cold spots. The system is also reversible and capable of providing chilled water for air conditioning.

  • Capacity: 3 to 12 tons
  • Efficiency: Up to 24.5 EER / 3.8 COP
  • Voltages: 208/230V, 60Hz, 1Ph (3-10 ton models only); 208/230V, 60Hz, 3Ph; 460V, 60Hz, 3Ph
  • Copeland UltraTech 2-stage compressor
  • Factory installed desuperheater

Es4 st

Two-Stage Indoor Split Unit | ST

The TETCO indoor split model offers unsurpassed flexibility of installation in both new construction and retrofit applications. The unit can be used alone or added to a conventional furnace/air conditioner in new or existing buildings, creating a hybrid heating and cooling system.

  • Capacity: 2 to 6 tons
  • Efficiency: Up to 30.5 EER / 4.9 COP
  • Voltages: 208/230V, 60Hz, 1Ph/3Ph
  • Copeland UltraTech 2-stage compressor
  • Factory installed desuperheater

Es4 rt

Two-Stage Outdoor Split Unit | RT

The TETCO Commercial Series outdoor split system has a space-saving footprint making it an excellent choice for applications with limited clearance. The unit can be used alone or added to a conventional heating/cooling system.

  • Capacity: 2 to 5 tons
  • Efficiency: Up to 25.4 EER / 4.4 COP
  • Voltages: 208/230V, 60Hz, 1Ph
  • Copeland UltraTech 2-stage compressor
  • Built-in freeze protection
  • Factory installed desuperheater circuit